Nellis Auction Logo
Explore Productsended

YJINGRUI Laminar Flow Hood, H-14 HEPA Filter with Safety Locks, Class 100/ ISO Class 5 Cleanliness, Fan Filter Unit 22.6x22.6in Flow Hood Mycology/Clean Room/Laboratory 110V

Photo 1 of YJINGRUI Laminar Flow Hood, H-14 HEPA Filter with Safety Locks, Class 100/ ISO Class 5 Cleanliness, Fan Filter Unit 22.6x22.6in Flow Hood Mycology/Clean Room/Laboratory 110V
1/3
Photo 1 of YJINGRUI Laminar Flow Hood, H-14 HEPA Filter with Safety Locks, Class 100/ ISO Class 5 Cleanliness, Fan Filter Unit 22.6x22.6in Flow Hood Mycology/Clean Room/Laboratory 110V
2/3
Photo 1 of YJINGRUI Laminar Flow Hood, H-14 HEPA Filter with Safety Locks, Class 100/ ISO Class 5 Cleanliness, Fan Filter Unit 22.6x22.6in Flow Hood Mycology/Clean Room/Laboratory 110V
3/3

Item Details

Pickup Location

4031 Market Center Dr Suite 303

North Las Vegas, NV, 89030

Quality

Used
Functional
Minor Damage
Assembly Required
In Package
Unknown if Missing Parts

Estimated Retail Price

$293.16

Buyers Premium

15%

Inventory Number

1054435084

Found in

Additional Details from the Manufacturer

This item information is coming from the manufacturer. Some of the details may vary from the Nellis Auction listing. Please check the Quality Rating and Notes for information specific to this listing

brand

YJINGRUI

color

slivery

size

22.6x22.6 Inch

weight

22.05 lbs

More features

  • [ Parameters ] Size:22.6x22.6in; Voltage:110v; Rated Air Flow:350-800m3/h; Air Velocity: 0.3-0.45-0.65s/m; Power: 145-165-185w; Noise: 55-60-65dB.
  • [ H-14 HEPA Filter ] Class 100/ ISO class 5 cleanliness laminar flow hood, can filtrate 99.995% of particles with a diameter of 0.3 micron
  • [ Adjustable Air flow velocity ] The air flow velocity through small laminar flow hood can be set in three speed. Average air flow velocity through filter is 0.45-0.60 m/s.
  • [ Notice ] HEPA filter can not be washed, usually it's replacement cycle is once every 6-12 months. If you need filter replacement, we will provide assistance within 24 hours.
  • [ Wide Application ] Our laminar flow hood filter can be used in clean room, mycology work, food processing workshop, pharmaceutical workshop, laboratory and operating room.